abstract = "An enzymatic corn wet milling process has been developed that replaces or reduces the use of sulfur dioxide (SO2) by using proteolytic enzymes. An acid fungal protease (GC106) was evaluated in this process, and its dose was optimized for starch yield using a laboratory enzymatic wet milling procedure.
Abstract: Selecting the optimal parameters for wet steam accumulator of steam‐powered catapult is an important task, due to launching safety. There is no …
At-scale industrial continuous twin screw wet granulation process was analyzed and optimized via design of experiment (DoE). The Box-Behnken method was selected to investigate the influence of key ...
Abstract. To establish an efficient and clean cooling tower, a mechanical draft wet cooling tower (MDWCT) with the condensation plume module is studied. ... and using the TOPSIS method to find the optimization dry and wet channels width and objective values. The results of the study can provide a reference for the use of condensation …
Abstract. Wet-surface heat exchangers are analyzed in order to determine the configuration that optimizes the performance. The objective is to cool a stream of air to a temperature lower than the inlet wet-bulb temperature by the evaporation of water. Three laboratory models and a commercial prototype were analyzed.
Through optimal combination of slurry circulating pumps, energy saving of the wet flue gas desulfurization (WFGD) system and operation optimization of the booster fan could be realized; the ...
2.4. Calculation and identification of optimization potentials. The wastewater treatment design for case study 2 of the food processing company was carried out …
Keisari and Shams [10] worked on the optimization of wet-steam nozzle shape. Ma et al. [11] studied the spontaneous condensation in the supersonic gas separation technology using converging ...
Abstract. This study attempts to quantify the potential improvement in a natural draft wet cooling tower (NDWCT) performance that can be attained by …
Stochastic bi-objective optimization for closed wet cooling tower systems based on a simplified analytical model. Author links open overlay panel Zhiyong Wu a b, Zhibin Lu a b, Bingjian Zhang a b, ... Show abstract. The core component in a closed-circuit cooling tower is the heat exchanger consisting of bundles of heat transfer tubes. To ...
Mixtures of acetaminophen (95%) with binders (5% povidone or partially pregelatinized starch) were wet granulated through twin screw extruder at 70°C by adding 7% w/w water. The process had a short granulation time (<1 min), and, on account of the elevated processing temperature used, no drying after extrusion was needed.
In addition, this optimization caused the erosion rate to be improved by 2.33% and the condensation losses to be decreased by 0.39%. The graphic schema of optimization loop of the blade trailing ...
Abstract. Ambient wet-bulb temperature measurement is critical in the water-cooled chiller plant system to enhance the holistic energy efficiency through advanced control strategies, such as the cooling tower temperature relief, condenser water supply temperature reset, and so on. ... Keywords: Optimization; Wet-bulb Temperature …
Section snippets Wet ESP design and configuration. The semispherical wet ESP designed for aerosol sampling is illustrated in Fig. 1. The wet ESP consisted of a dome with an inner diameter of 10 cm and a length of 65 cm, fabricated from antistatic slippery polyethylene (McMaster-Carr, LA, CA, USA) with a thickness of 3.175 mm. Inlet and …
Abstract. A fast and accurate representation of the complex heat and mass transfer processes of closed-wet cooling tower (CWCT) systems for optimal design and …
Optimization of a wet scrubber with electrolyzed water spray-Part II: Airborne culturable bacteria removal. Li Z 1, Li B 1 ... To arrive at the top five similar articles we use a word-weighted algorithm to compare words from the Title and Abstract of each citation. Optimization of a wet scrubber with electrolyzed water spray-Part I: Ammonia ...
Abstract. This paper works on the optimization of wet-steam nozzle shape. Employment of Navier–Stokes viscous flow equations which are coupled with a two equation k – ω based SST turbulent model, with a finite volume discretization and fully Eulerian reference frame for both phases provide an appropriate numerical modeling to …
Abstract. In the present study, an attempt has been made to coat the non-conductive Ultra-high Molecular Weight Polyethylene (UHMWPE) fibers with Low …
Abstract. A fast and accurate representation of the complex heat and mass transfer processes of closed-wet cooling tower (CWCT) systems for optimal design and …
Abstract. A fast and accurate representation of heat and mass transfer processes of closed-wet cooling tower (CWCT) systems for optimal design and optimization is still challenging, especially considering the …
Paul Kah. International Journal of Mechanical and Materials Engineering 9, Article number: 26 ( 2014 ) Cite this article. 4915 Accesses. 8 Citations. Metrics. …
Optimization of a high shear wet granulation process using focused beam reflectance measurement and particle vision microscope technologies J Pharm Sci. 2011 Aug ... Abstract Application of process analytical technology in the pharmaceutical industry has led to a great number of studies into inline instrumentation. Near-infrared moisture ...
The three optimization output values are 23.62 °C, 16.31%, and 0.018 kg/kg, and the corresponding wet and dry channels width are 0.03 m and 0.02 m respectively. Introduction The world is currently facing a serious water shortage, especially in China, where the per capita water possession rate is only 25% of the world average value [1,2].
Abstract. This study attempts to quantify the potential improvement in a natural draft wet cooling tower (NDWCT) performance that can be attained by optimizing the fill and water distribution ...
[Show full abstract] 50 % KOH (40 °C) chemical wet etching was applied to increase the fracture stress of the Si cantilever. The fracture stress in the both of Si{100} and Si{110} cantilevers ...
Abstract. Wet steam flow in the low-pressure stage of a steam turbine reduces efficiency and causes blade erosion due to the formation of water droplets. To enhance efficiency and lifetime, shape optimization is a suitable method, but it requires computationally expensive numerical simulations of non-equilibrium condensation in 3D …
Li et al. (2019) also stated in their research on the optimization of a wet scrubber with electrolyzed water in ammonia absorption that the pH of the solution is the most important factor in ...
Optimum conditions for hemicellulose solubilization and cellulose convertibility were for 60 g l −1 straw: 185°C, 6.5 g l −1 Na 2 CO 3, and 12 bar O 2 with a 15-min reaction time. Under these conditions, 55% of the lignin and 80% of the hemicellulose were solubilized, while 95% of the cellulose remained in the solid fraction.
Optimization of these factors was able to achieve 98.3% of bioethanol yield at the process conditions of substrate loading = 30.4 w/v, temperature = 55.8 °C, reaction time = 5.2 h, pH = 5.2, and ...
Wet flue gas desulfurization systems (WFGD) are the most popular method to remove the SO2 from the flue gas in China's power plants. Most WFGD systems contain an oxidation subsystem, which is ...
The optimization of the wet ESP configuration for maximum collection efficiency and lower ozone generation was achieved by adjusting the flow rate and applied voltage. To assess the performance of the wet ESP, we conducted concurrent field experiments using three different sampling methods: the wet ESP, the VACES system …